Interactive Transcript
0:01
An important concept in cardiac CT imaging is temporal
0:05
resolution, which, quite simply, is the shutter speed.
0:12
So what is shutter speed?
0:14
Well, imagine you're on a train and
0:16
you're taking a picture of a tree.
0:18
The train is moving.
0:22
The shutter speed is how quickly your
0:23
camera takes a picture of the tree.
0:27
Keeping that same analogy, if you slow the
0:29
train down for whatever shutter speed you
0:32
have, you get a better picture of the tree.
0:34
So in a similar way, if you slow the heart rate
0:38
down, you get better use of your temporal resolution.
0:41
But the temporal resolution, shutter speed,
0:44
is essentially dependent on how quickly
0:46
the gantry, which is the CT gantry, rotates.
0:50
So it depends on the gantry rotation speed,
0:54
and therefore the gantry rotation time.
0:56
One of the interesting things about CT,
0:59
which is in contrast to MR, is that in CT,
1:05
temporal resolution and spatial resolution
1:08
are generally not related to each other.
1:12
Whereas in MR, they are directly related.
1:14
Not necessarily temporal resolution, but acquisition
1:16
time, because in MR, to improve the spatial
1:20
resolution, we need to increase the matrix size
1:23
which means we need to increase the scan time.
1:26
Thankfully with CT, we don't have that, and
1:29
that may be one of many reasons why CT
1:31
coronary took off, whereas MR coronary didn't.
1:36
So what are the factors affecting
1:38
the temporal resolution?
1:39
Well, as I mentioned, the most important
1:41
factor is the gantry rotation time.
1:44
The gantry has the detectors and has the X-ray source.
1:50
The X-rays go through the body, and the detectors
1:53
on the other side are looking, but the gantry only
1:58
needs to rotate halfway in order to see the whole
2:02
body, since some detector or the other would
2:05
have seen one part of the body and they can kind
2:09
of interpolate or extrapolate the other part.
2:13
So the actual temporal resolution is
2:15
gantry rotation time divided by two.
2:17
In reality, it's slightly more than two.
2:21
Because you have this fan beam that you need to take
2:23
into consideration, which is about 30 degrees, so you
2:25
have to factor in a rotation arc of about 210 degrees.
2:30
But essentially, to keep things simple,
2:33
it's gantry rotation time divided by 2.
2:37
Gantry rotation times used to be a
2:40
lot, and thanks to smart engineering,
2:44
gantries are getting faster and faster.
2:46
The rotation time is getting faster and faster.
2:49
Lower and lower.
2:51
So we're talking about 260 milliseconds now as
2:55
the best, but yes, it can go up to about 500.
3:00
The second thing is whether you have one
3:05
source of X-ray, one source of X-ray, and
3:09
therefore complementary detector or two.
3:12
The two sources are two X-rays.
3:16
At right angles to each other, and what you do
3:17
there is, instead of having to go through 180,
3:21
you only need to go through 90, and between one
3:25
source and the 90-degree place, the other source
3:28
going through 90 degrees, and you can just kind of
3:30
imagine it in your mind, you can see the whole body.
3:34
With a single source, you need to go through 180,
3:37
because once you've seen it through one end,
3:38
you don't need to see it through the other end.
3:41
With dual source, you need to go through at 90 because
3:43
you have one detector that sees 90 degrees, the other
3:46
detector sees 90 degrees, and together, they see everything.
3:51
So, the third thing is something that
3:56
probably isn't used as much these days because
3:59
the temporal resolution, by virtue of the
4:01
gantry rotation speed, has improved so much.
4:05
And that's called multi-segment reconstruction.
4:07
But I think it's worth understanding because it really
4:10
gets to the heart of multiple things in cardiac CT.
4:16
So what happens with a single-segment reconstruction,
4:18
which is the way to do it without invoking more
4:25
than one cardiac cycle, is that the gantry rotates and
4:33
CT sees one element of the heart in one
4:37
phase of the cardiac cycle in one cycle.
4:40
So let's say the left main, it sees 60 percent
4:43
of the cardiac cycle in one heart interval.
4:46
With multi-segment, what the gantry
4:48
is doing is it's saying, "Okay."
4:53
I have one detector that looks at the left main at 60%
4:56
of the cardiac cycle in heartbeat 5, and I have
5:00
another detector which looks at the left main origin
5:05
at the same phase of the cardiac cycle in heart rate 6.
5:08
So we'll make each of these just go through a partial
5:14
arc and improve our temporal resolution accordingly.
5:18
So, it takes that whole concept of partial scanning
5:25
and extends it to another level.
5:28
And it's able to do this because each part
5:32
of the heart, when the pitch is low enough,
5:36
each part of the heart in each phase of the
5:38
cardiac cycle is seen by more than one detector.
5:42
So there's information that we can use, and we
5:46
can just use what one detector has seen through a
5:50
small arc, another detector seen through another
5:53
small arc, but splice the two arcs together.
5:56
Okay.
5:58
And that's essentially what you're doing, and you
6:00
see here that with single-segment partial scan
6:07
reconstruction, one heartbeat gives you one part.
6:12
Next heartbeat you go down, next heartbeat
6:15
you go further down, so you're kind of
6:16
going through the anatomy in three different
6:19
heartbeats, same part of the cardiac cycle.
6:22
With multi-segment reconstruction, you're now
6:25
using those three heartbeats and three different
6:30
detectors to reconstruct the same place.
6:35
That's the key difference.
6:37
You can do that using two, and you use
6:40
that doing three or four heartbeats.
6:42
There's obviously a limit to how many you
6:45
can use because you only have so many
6:47
detectors, and you can only go so slow.
6:50
But what it does is it reduces the temporal
6:53
resolution by a factor, and that factor is the
6:56
number of heartbeats used to reconstruct the image.
6:58
So if it's two, divide it by two.
7:00
If it's four, divide it by four.
7:03
So, the first thing that will
7:05
be obvious over here is that.
7:08
For this to work, the heart rate needs to be
7:11
very, very regular, because if the heart rate
7:15
is not regular, what you think is 60 percent of
7:18
the cardiac cycle in beat one, 60 percent of the
7:21
cardiac cycle in beat five may be very different.
7:23
And for those to be different simply means
7:26
they're at different phases of contraction
7:27
or relaxation, and therefore when you stitch
7:30
them together, you get misregistration.
7:32
So that's one problem.
7:33
So it has to be very regular.
7:35
The second is that for this to be useful,
7:39
the heart rate needs to be a little bit fast.
7:42
You know, in the order of 80 to 90, or even
7:45
70 to 80, um, because the pitch is low.
7:49
And if the heart rate is slow and the pitch is low,
7:52
we're talking about dramatically increased scan times.
7:56
Does it make a difference?
7:59
It definitely makes a difference.
8:00
It makes a difference both in terms of increasing,
8:04
you know, freezing the heart, you know, that's a term
8:06
used for having a high enough temporal resolution
8:09
that you can overcome the motion of the heart.
8:13
But most importantly, creating an image without
8:16
stair step artifacts, creating a more uniform image.
8:20
Because whenever you have stair step artifacts, there
8:22
is a tendency to overcore stenosis at that stair step.
8:28
So yes, it definitely makes a difference, again, going
8:31
from single on the left to multiple on the right.
8:37
And all of this, I think, gets to a very important
8:40
physiological point with cardiac imaging, which
8:44
is that the diastolic component of the cardiac cycle,
8:50
which is a component where the heart is moving less.
8:55
There are certain parts of the diastolic component of
8:58
the cardiac cycle where the heart moves even less, but
9:02
as a general rule, the heart moves less in diastole than in
9:05
systole, of course, because systole is contracting.
9:07
The diastolic component of
9:09
the cardiac cycle is variable.
9:14
When the heart rate is low, the diastolic component
9:17
is longer relative to the actual heart rate
9:22
or RR interval when the heart rate increases,
9:25
the diastolic component shrinks and it's the systolic
9:28
component that is relatively fixed, and you can see
9:31
in the graph there how the length of the diastolic
9:35
component varies with the heart rate, and that has a
9:40
consequence, and the consequence is that when you have
9:44
a gantry with a rotation time of 250 milliseconds,
9:48
what that gantry rotation is doing, what it's
9:51
doing is it's basically seeing 250 milliseconds
9:55
of what has happened during that cardiac cycle.
9:59
And that 250 milliseconds may not be much
10:04
of a, maybe the same if you're in diastole.
10:08
So what happened in the beginning
10:09
of the 250 is the same as the end.
10:12
But if the heart rate is fast,
10:16
and the diastolic time is short,
10:18
shrunk to 100 milliseconds.
10:20
Now that 250 milliseconds is not only
10:23
seen in diastole, but also seen in systole.
10:24
And that's where motion artifacts come in.
10:28
So, yep.
10:28
So everything nicely ties up when you think
10:30
about cardiac imaging, always think a little
10:33
bit about the physiology, the heart rate, the RR
10:37
interval, and how everything fits in together.
10:40
Thank you.
© 2024 MRI Online. All Rights Reserved.